PSH-821 Series (300W-5000W) Transformer Based Low Frequency Pure Sine Wave Solar Inverter
General Features
Transformer based high reliability circuit design, combined with advanced SPWM technology.
Pure sine wave output, suitable for all kinds of home appliances, especially for the motorized appliances.
Built-in MPPT solar charge controller.
Comprehensive management of solar charger and AC charger.
Complete protection functions
Stabilized output voltage at AC mode (AVR mode).
Designed for both Lead Acid battery and LiFePO4 battery
Optional RS232/USB/WiFi communication port.
Optional wired remote controller with display.Technical Specifications
| MODEL | PSH-821-300W | PSH-821-600W | PSH-821-1000W | PSH-821-1600W | PSH-821-2000W | PSH-821-3000W | PSH-821-4000W | PSH-821-5000W |
|---|---|---|---|---|---|---|---|---|
| INVERTER OUTPUT | ||||||||
| Rated Power |
300VA/300W |
600VA/600W | 1000VA/1000W | 1600VA/1600W | 2000VA/2000W | 3000VA/3000W | 4000VA/4000W |
5000VA/5000W |
| Battery Voltage |
12VDC |
12VDC / 24VDC | 24VDC | 24VDC / 48VDC | 48VDC | |||
| Surge Power | 900VA | 1800VA | 3000VA | 4800VA | 6000VA | 9000VA | 12000VA |
15000VA |
|
Output Waveform |
Pure Sine Wave | |||||||
| Nominal Output Voltage | 220/230VAC ㊣5% or 110/120VAC㊣5% | |||||||
| Output Frequency | 50Hz / 60Hz | |||||||
| Efficiency |
Max 85% |
|||||||
| Dual Output | Optional, for critical load and non-critical load | |||||||
| AC MODE (AVR MODE) | ||||||||
| Nominal Input Voltage |
220/230VAC or 110/120VAC |
|||||||
| Input Voltage Range | 145-280VAC or 80-140VAC | |||||||
| Input Frequency | 50Hz / 60Hz | |||||||
|
AVR Output Voltage |
220/230VAC ㊣10% or 110/120VAC㊣10% |
|||||||
| Output Frequency |
Same as input frequency |
|||||||
|
Transfer Time |
not more than 10ms | |||||||
| BATTERY | ||||||||
| Battery Type |
Flooded battery, AGM/Gel battery, LiFePO4 battery, Sodium battery |
|||||||
| Nominal Battery Voltage |
12VDC |
12VDC / 24VDC |
24VDC |
24VDC / 48VDC |
48VDC |
|
||
| Max Charging Voltage | 12VDC: 14.4VDC default, 13.6-15VDC adjustable (0.1VDC incremental) | |||||||
|
24VDC: 28.8VDC default, 27.2-30VDC adjustable (0.2VDC incremental) |
||||||||
|
48VDC: 57.6VDC default, 54.4-60VDC adjustable (0.4VDC incremental) |
||||||||
| Floating Charging Voltage | 12VDC: 13.8VDC default, 13.2-14.4VDC adjustable (0.1VDC incremental) | |||||||
|
24VDC: 27.6VDC default, 26.4-28.8VDC adjustable (0.2VDC incremental) |
||||||||
|
48VDC: 55.2VDC default, 52.8-57.6VDC adjustable (0.4VDC incremental) |
||||||||
| SOLAR CHARGER & AC CHARGER | ||||||||
| Type of Solar Charger | PWM / MPPT |
MPPT |
||||||
|
Max PV Input Voltage |
75VDC |
105VDC |
150VDC | |||||
| MPPT Range | 16-55VDC |
16-75VDC / 32-75VDC |
32-75VDC |
32-135DC / 60-135VDC |
60-135VDC |
|||
| Max PV Charging Current | 25A / 50A |
50A / 80A |
50A / 80A |
|||||
| Max AC Charging Current |
10A |
15A | 20A / 15A | 20A | 20A / 15A | 20A | 20A | |
| Max Total Charging Current | 60A | 65A | 100A | 100A | 100A | 100A | 100A | 100A |
| DISPLAY & PROTECTIONS | ||||||||
| LCD Display |
AC current and power, output voltage, input voltage, operating frequency, charging current and power, battery voltage, PV power |
|||||||
| Inverter Protections |
Over voltage, under voltage, short circuit, overload, over temperature, spike&surge |
|||||||
| Optional Built-in Combiner Box | N/A |
Battery breaker, PV lightning protector, PV input circuit breaker, AC Input circuit breaker, RCCD (residual current circuit breaker) |
||||||
| OPERATING CONDITIONS | ||||||||
| Storage Temperature |
-10∼C ~ 40∼C |
|||||||
| Operating Temperature |
-15∼C ~ 40∼C |
|||||||
|
Operating Humidity |
10%-90%, non-condensing |
|||||||
|
PACKING |
||||||||
|
Product Weight (kgs) |
7.5 | 11 | 13 | 15 | 17 | 20 | 22 | 24 |
|
Product Size (WxHxD mm) |
380x260x165 | 440x290x170 |
500x300x200 |
|||||
| Colorbox Size (LxWxH mm) | 426x300x202 | 518x348x218 | N/A | |||||
| Carton Size (LxWxH mm) | 440x313x423 | 532x360x236 |
680x320x400 |
|||||
| Qty / Carton (pcs) | 2 | 1 |
1 |
|||||