IVR Series (10kVA-100kVA) Three Phase Industrial Servo Motor Voltage Stabilizer
Typical Applications:
¡ñ Multi-color printing machines
¡ñ Air compressors
¡ñ CNC machines
¡ñ Punching machines
¡ñ Laser cutting machines
¡ñ Welding machines
¡ñ Home appliances
General Features
Three phase compensation servo motor technology.
Wide AC input voltage range.
100% unbalanced loading capability between three phases.
Digital display for voltage and current.
Isolated manual bypass switch.
Full protections such as under/over voltage, overload, over temperature, phase failure protections.
Selectable 6s/180s delay time.
Optional surge/spike protection (replaceable SPD).
Optional isolation transformer at output end.
Optional RS232/RS485.
Technical Specifications
GENERAL | ||||
Technology | Servo motor technology | |||
Efficiency | >90% | |||
Delay Time | 6s / 180s selectable | |||
INPUT | ||||
Input Voltage Range | 276-450V / 173-450V | |||
Input Frequency Range |
45-65Hz | |||
OUTPUT | ||||
Rated Output Voltage |
380V / 400V | |||
Output Precision |
¡À3% / ¡À1% |
|||
Response Time |
<1s, against 10% variation of input voltage | |||
Loading Ability |
120% for 180s, 150% for 30s, 200% for 10s, 300% for 5s |
|||
DIGITAL DISPLAY | ||||
Input Voltage | Line voltage: AB, BC, CA Phase voltage: A, B, C | |||
Output Voltage | Line voltage: ab, bc, ca Phase voltage: a, b, c | |||
Output Current | a, b, c | |||
PROTECTIONS | ||||
Over Voltage | Output cutoff by contactor + Error code "H" + Buzzer beeping | |||
Under Voltage |
Output cutoff by contactor + Error code "L" + Buzzer beeping |
|||
Over Temperature |
Output cutoff by contactor + Error code "C" + Buzzer beeping |
|||
Overload |
Output cutoff by contactor + Error code "F" + Buzzer beeping |
|||
Phase Failure |
Output cutoff by contactor + Buzzer beeping |
|||
Short Circuit | Input cutoff by air breaker | |||
Wrong Phase Sequence | AVR can't be switched on | |||
Manual Bypass | Yes, isolated bypass switch or interlocked bypass switch | |||
Surge/Spike (Optional) |
Replaceable SPD |
|||
RS232/RS485 | ||||
Parameters |
Input voltage, output voltage, output current | |||
AVR Status |
Power on/offf, AVR/Bypass, phase failure, output under voltage, output over voltage, over temperature, overload, "N" wire loss | |||
Status of Cabinet | Open/close | |||
SAFETY | ||||
1Insulation Voltage |
2,000V / 60s |
|||
Insulation Resistance |
>5M¦¸ |
|||
Creepage Distance |
>8mm |
|||
Grounding Resistance |
<0.1m¦¸ |
|||
Insulation Class of Coil |
Class F (155¡æ) |
|||
Cooling Mode |
Smart Cooling Fan |
|||
IP Level |
IP20 |
|||
OPERATING CONDITIONS | ||||
Storage Temperature |
-15¡ãC ~ 45¡ãC |
|||
Operating Temperature |
-5¡ãC ~ 40¡ãC |
|||
Operating Humidity |
10%-90%, non-condensing |
Model
Rated Power
Product Size (DxWxH mm)
Product Weight (kgs)
Packing Size (LxWxH mm)
Gross Weight (kgs)
IVR-10K
10kVA / 6kW
520 x 460 x 830
70
550 x 600 x 1000
85
IVR-15K
15kVA / 9kW
520 x 460 x 830
78
550 x 600 x 1000
93
IVR-20K
20kVA / 12kW
520 x 460 x 830
100
550 x 600 x 1000
115
IVR-30K
30kVA / 18kW
520 x 460 x 830
108
550 x 600 x 1000
128
IVR-45K
45kVA / 36kW
600 x 520 x 1080
175
620 x 680 x 1220
195
IVR-60K
60kVA / 48kW
600 x 520 x 1080
190
620 x 680 x 1220
210
IVR-80K
80kVA / 64kW
600 x 570 x 1080
210
680 x 750 x 1400
230
IVR-100K
100kVA / 80kW
600 x 570 x 1080
235
680 x 750 x 1400
260