IVR Series (10kVA-100kVA) Three Phase Industrial Servo Motor Voltage Stabilizer
Typical Applications:
♂ Multi-color printing machines
♂ Air compressors
♂ CNC machines
♂ Punching machines
♂ Laser cutting machines
♂ Welding machines
♂ Home appliances
General Features
Three phase compensation servo motor technology.
Wide AC input voltage range.
100% unbalanced loading capability between three phases.
Digital display for voltage and current.
Isolated manual bypass switch.
Full protections such as under/over voltage, overload, over temperature, phase failure protections.
Selectable 6s/180s delay time.
Optional surge/spike protection (replaceable SPD).
Optional isolation transformer at output end.
Optional RS232/RS485.
Technical Specifications
GENERAL | ||||
Technology | Servo motor technology | |||
Efficiency | >90% | |||
Delay Time | 6s / 180s selectable | |||
INPUT | ||||
Input Voltage Range | 276-450V / 173-450V | |||
Input Frequency Range |
45-65Hz | |||
OUTPUT | ||||
Rated Output Voltage |
380V / 400V | |||
Output Precision |
㊣3% / ㊣1% |
|||
Response Time |
<1s, against 10% variation of input voltage | |||
Loading Ability |
120% for 180s, 150% for 30s, 200% for 10s, 300% for 5s |
|||
DIGITAL DISPLAY | ||||
Input Voltage | Line voltage: AB, BC, CA Phase voltage: A, B, C | |||
Output Voltage | Line voltage: ab, bc, ca Phase voltage: a, b, c | |||
Output Current | a, b, c | |||
PROTECTIONS | ||||
Over Voltage | Output cutoff by contactor + Error code "H" + Buzzer beeping | |||
Under Voltage |
Output cutoff by contactor + Error code "L" + Buzzer beeping |
|||
Over Temperature |
Output cutoff by contactor + Error code "C" + Buzzer beeping |
|||
Overload |
Output cutoff by contactor + Error code "F" + Buzzer beeping |
|||
Phase Failure |
Output cutoff by contactor + Buzzer beeping |
|||
Short Circuit | Input cutoff by air breaker | |||
Wrong Phase Sequence | AVR can't be switched on | |||
Manual Bypass | Yes, isolated bypass switch or interlocked bypass switch | |||
Surge/Spike (Optional) |
Replaceable SPD |
|||
RS232/RS485 | ||||
Parameters |
Input voltage, output voltage, output current | |||
AVR Status |
Power on/offf, AVR/Bypass, phase failure, output under voltage, output over voltage, over temperature, overload, "N" wire loss | |||
Status of Cabinet | Open/close | |||
SAFETY | ||||
1Insulation Voltage |
2,000V / 60s |
|||
Insulation Resistance |
>5M次 |
|||
Creepage Distance |
>8mm |
|||
Grounding Resistance |
<0.1m次 |
|||
Insulation Class of Coil |
Class F (155⊥) |
|||
Cooling Mode |
Smart Cooling Fan |
|||
IP Level |
IP20 |
|||
OPERATING CONDITIONS | ||||
Storage Temperature |
-15∼C ~ 45∼C |
|||
Operating Temperature |
-5∼C ~ 40∼C |
|||
Operating Humidity |
10%-90%, non-condensing |
Model
Rated Power
Product Size (DxWxH mm)
Product Weight (kgs)
Packing Size (LxWxH mm)
Gross Weight (kgs)
IVR-10K
10kVA / 6kW
520 x 460 x 830
70
550 x 600 x 1000
85
IVR-15K
15kVA / 9kW
520 x 460 x 830
78
550 x 600 x 1000
93
IVR-20K
20kVA / 12kW
520 x 460 x 830
100
550 x 600 x 1000
115
IVR-30K
30kVA / 18kW
520 x 460 x 830
108
550 x 600 x 1000
128
IVR-45K
45kVA / 36kW
600 x 520 x 1080
175
620 x 680 x 1220
195
IVR-60K
60kVA / 48kW
600 x 520 x 1080
190
620 x 680 x 1220
210
IVR-80K
80kVA / 64kW
600 x 570 x 1080
210
680 x 750 x 1400
230
IVR-100K
100kVA / 80kW
600 x 570 x 1080
235
680 x 750 x 1400
260