TVR-104 Series ( 0.5kVA-10kVA) Triac Control Voltage Stabilizer
TVR is one kind of the most popular solid state voltage stabilizers, in which the Triac is used as the tap switcher. Compared to traditional relay or servo motor type voltage stabilizers, it has unique advantages such as no sparkle, double life span, higher output precision, wide input voltage range,etc. TVR can be used for almost all the home & office appliances, especially good for those who require a higher regulating speed.
♂ Refrigeration equipments: fan, refrigerator, chest freezer, cooler
♂ Entertainment appliances: TV, DVD, VCR, DVB, HiFi
♂ IT & Office equipments: PC, workstation, fax machine, photocopier
♂ Heating systems: gas boiler, circulation pump
General Features
Immediate voltage regulating, response time <50ms.
Zero cross transfer technology, output waveform is more smooth.
Static contactless regulating, no switching sparkle, no mechanical noise.
Independent protection circuit to prevent Triac from mis-trigger.
Protection of over voltage, under voltage, coil over temperature, overload,out of frequency, short circuit, out of frequency.
Double protection circuit to protect appliances (eletromagnetic relay based) in case of triac faulty.
High output precision up to 4%. Audible and visible alarm (buzzer beeping + LED indicators).
Soft start function to avoid home circuit breaker trips off.
Optional manual bypass switch.
Technical Specifications
| MODEL | TVR-104-500VA | TVR-104-1000VA | TVR-104-1500VA | TVR-104-2000VA | TVR-104-3000VA | TVR-104-5000VA | TVR-104-8000VA | TVR-104-10000VA |
|---|---|---|---|---|---|---|---|---|
| Rated Power | 500VA | 1000VA | 1500VA | 2000VA | 3000VA | 5000VA | 8000VA | 10000VA |
| GENERAL | ||||||||
| Technology | Solid state relay (Triac) tap change + Zero cross transfer technology | |||||||
| Transformer | Toroidal transformer | |||||||
|
Material of Cabinet |
Plastic front panel + Metal case | |||||||
| Efficiency | >95% | |||||||
| Response Time | <50ms | |||||||
| Input Frequency | 45-65Hz | |||||||
| Delay Time | 6s / 180s selectable | |||||||
| INPUT VOLTAGE & OUTPUT VOLTAGE | ||||||||
|
220V |
Option 1: Input 120-280V, Output 220V㊣5% | |||||||
| Option 2: Input 95-260V, Output 220V㊣8%. and when Input 140-250V, Output 220V ㊣ 4% | ||||||||
|
Option 3: Input 140-250V, Output 220V㊣4% |
||||||||
| 230V | Option 1: Input 140-265V, Output 230V㊣4% | |||||||
| Option 2: Input 100-265V, Output 230V㊣8% | ||||||||
| MULTIFUNCTIONAL DISPLAY | ||||||||
| Digital Display | Input voltage, Output voltage | |||||||
| LED Indicators | Green LED: Power on; Yellow LED: Delaying; Red LED: Protecting (output cutoff) | |||||||
| PROTECTIONS | ||||||||
| Over Voltage | Output cutoff + Red LED + Error code "H" | |||||||
|
Under Voltage |
Output cutoff + Red LED + Error code "L" |
|||||||
| Over Temperature for Triac |
When temperature of heat sink is >80⊥: Output cutoff + Red LED + Error code "C" ; when temperature of heat sink is <60⊥, output restores |
|||||||
| Over Temperature for Transformer |
When temperature of transformer is >120⊥: Output cutoff + Red LED + Error code "t"; when temperature of transformer is <100⊥, output restores |
|||||||
|
Overload |
Once it goes into overload protection status, it will retry to restore output after 3 min, totally it will retry 3 times. Output cutoff + Red LED + Error code "P" |
|||||||
| Out of Frequency |
Output cutoff + Red LED + Error code "F" |
|||||||
| Other Errors |
Output cutoff + Red LED + Error code "E" |
|||||||
| Short Circuit | Circuit breaker tirps off | |||||||
| Surge/Spike (Optional) |
1 x MOV (L-N) or 3 x MOV (L-N, L-E, N-E) |
|||||||
| Soft Start | Only available for 3000-10000VA | |||||||
|
OTHER OPTIONAL FUNCTIONS |
||||||||
| Bypass |
Manual bypass switch (only available for 3000-10000VA) |
|||||||
|
Cooling Fan for Triac |
When temperature of heat sink is >50⊥, cooling fan starts to work; when temperature of heat sink is <40⊥, cooling fan stops |
|||||||
|
Coolign Fan for Transformer |
**only available for for 8000-10000VA** when temperature of transformer is >60⊥, cooling fan starts to work; when temperature of transformer is <40⊥, cooling fan stops |
|||||||
| CERTIFICAITONS | ||||||||
|
Certification |
CE, CB, SON, SASO, RoHS 2.0 |
|||||||
| OPERATING CONDITIONS | ||||||||
| Storage Temperature |
-15∼C ~ 40∼C |
|||||||
| Operating Temperature |
-15∼C ~ 40∼C |
|||||||
|
Operating Humidity |
10%-90%, non-condensing |
|||||||
|
PACKING |
||||||||
|
Product Size (WxHxD mm) |
140x175x250 |
162x200x267 |
215x268x307 |
260x315x425 |
||||
| Inner Box Size (LxWxH mm) | 305x165x220 |
337x197x238 |
343x258x300 |
460x300x358 |
||||
| Carton Size (LxWxH mm) |
345x318x444 |
605x345x258 |
531x353x315 |
480x320x382 |
||||
| Qty / Carton (pcs) | 4 |
3 |
2 |
1 |
||||